INSULATED FUNCTIONAL ROOFS DESIGNED FOR VEHICLE ROUTES

Description of Figure
  1. Sett of thickness in accordance with the standards and guidelines
  2. Base of sand and cement
  3. Layer for loads distribution - made of breakstone min. 150 mm thick
  4. Nonwoven for filtration fixed with 20cm overlaps
  5. Matt for drainage
  6. Nonwoven for filtration
  7. Thermal insulation - XPS boards
  8. Two layers of separating-slip film, fixed with 10 cm overlaps
  9. IZOLMAT PLAN PYE PV250 S5,0 – Heat-welded underlay membrane
  10. IZOLMAT PLAN PYE G200 S4,0 or IZOLMAT PLAN PYE PV180 S4,0 – Heat-welded underlay membrane
  11. Asphalt impregnant - IZOHAN PENETRATOR G7 alternatively: IZOHAN BR or IZOHAN DYSPERBIT diluted with water
  12. Concrete substrate executed with slope